Search results for " data acquisition"
showing 10 items of 22 documents
The data acquisition system for the ANTARES neutrino telescope
2006
The ANTARES neutrino telescope is being constructed in the Mediterranean Sea. It consists of a large three-dimensional array of photo-multiplier tubes. The data acquisition system of the detector takes care of the digitisation of the photo-multiplier tube signals, data transport, data filtering, and data storage. The detector is operated using a control program interfaced with all elements. The design and the implementation of the data acquisition system are described.
Real-Time Power Flow Monitoring and Control System for Microgrids Integration in Islanded Scenarios
2019
This article presents an enhanced system for real-time power flow monitoring and control (PFMC) for microgrids integration in medium-voltage (MV) distribution networks. The developed solution includes both system architecture and the monitoring and control algorithms, and it has low implementation and installation costs. It is based on the use of hardware and software solutions previously proposed by the authors, i.e., a distributed measurement, a control and communication architecture, and a supervisory control and data acquisition (SCADA) software, which have been enhanced and integrated for the considered application. The SCADA implements a load flow (LF) algorithm for real-time power fl…
The ATLAS Data Acquisition and High Level Trigger system
2016
Journal of Instrumentation 11(06), P06008 (2016). doi:10.1088/1748-0221/11/06/P06008
Characterization of a neutron–beta counting system with beta-delayed neutron emitters
2016
A new detection system for the measurement of beta-delayed neutron emission probabilities has been characterized using fission products with well known β-delayed neutron emission properties. The setup consists of BELEN-20, a 4π neutron counter with twenty 3He proportional tubes arranged inside a large polyethylene neutron moderator, a thin Si detector for β counting and a selftriggering digital data acquisition system. The use of delayed-neutron precursors with different neutron emission windows allowed the study of the effect of energy dependency on neutron, β and β-neutron rates. The observed effect is well reproduced by Monte Carlo simulations. The impact of this dependency on the accura…
Electrical distribution substation remote diagnosis and control system
2014
This paper presents the conception, design, set up and realization of a prototype system for telemanagement of a MV/LV substation. The prototype has been developed according to the current standards. This system allows to monitor the status of the MV/LV substation box, of the medium voltage equipment, of the transformer and of the low voltage equipment. In particular, the system acts when some specified events occur. The prototype has been realized by using a DAQ; the software that implement the telemanagement system has been developed in LabVIEW environment. The system allows a remote monitoring of the quantities of interest that is carried out using the TeamViewer software able to establi…
Development of a high-accuracy PC-based wattmeter with commercial data acquisition boards
2011
This paper presents the development of a high accuracy sampling wattmeter, which makes use of two commercial data acquisition boards (DAQs) connected to a common personal computer. Commercial software is also used for data processing and implementation of the virtual instrument. The set up of the PC-based wattmeter is described and a preliminary evaluation of its metrological performances is made by means of two series of experimental tests, which were carried out with an electric power standard and a high performance multifunction calibrator. © 2011 IEEE.
Conceptual design of the TRACE detector readout using a compact, dead time-less analog memory ASIC
2015
[EN] The new TRacking Array for light Charged particle Ejectiles (TRACE) detector system requires monitorization and sampling of all pulses in a large number of channels with very strict space and power consumption restrictions for the front-end electronics and cabling. Its readout system is to be based on analog memory ASICs with 64 channels each that sample a View the MathML source window of the waveform of any valid pulses at 200 MHz while discarding any other signals and are read out at 50 MHz with external ADC digitization. For this purpose, a new, compact analog memory architecture is described that allows pulse capture with zero dead time in any channel while vastly reducing the tota…
The Belle II vertex detector integration
2019
Belle II DEPFET, PXD, and SVD Collaborations: et al.
Characterization of a neutron-beta counting system with beta-delayed neutron emitters
2016
Abstract A new detection system for the measurement of beta-delayed neutron emission probabilities has been characterized using fission products with well known β-delayed neutron emission properties. The setup consists of BELEN-20, a 4π neutron counter with twenty 3He proportional tubes arranged inside a large polyethylene neutron moderator, a thin Si detector for β counting and a self-triggering digital data acquisition system. The use of delayed-neutron precursors with different neutron emission windows allowed the study of the effect of energy dependency on neutron, β and β–neutron rates. The observed effect is well reproduced by Monte Carlo simulations. The impact of this dependency on …
DAQs-based wattmeters for high accuracy measurements. Comparison with the Italian power primary standard
2013
Abstract This paper is focused on the use of data acquisition boards (DAQs) for the development of high accuracy PC-based instruments for the measurements of electrical power. The proposed systems are simple, portable and low cost because they are based on commercial data acquisition boards (DAQs) connected to a common personal computer. Data processing is carried out by a commercial software based on an interpolating windowed FFT. In the paper it is shown how the voltage can be sensed directly, thanks to the DAQ input range, thus avoiding expensive voltage dividers. The set up of the DAQs-based solutions is described and the evaluation of their metrological features is made by means of a c…